See faults in Rack PDUs
Every PDU is mapped from inlet to outlet, with Critical and Warning faults that close themselves when the problem clears.
Asama catches issues across your system hardware, firmware, OS and orchestration in your data centers.
Read-only by default · No training on your data · SOC 2 Type II
Asama uses deep machine learning algorithms to dynamically baseline what normal looks like for every host, every workload and their peer groups. Our investigative approach helps spot hardware faults, performance anomalies, configuration drifts and security exposures that other tools miss.
Existing tools in the market focus on dashboard-led and alerting-first approaches, which are counterproductive especially when problems appear across the infrastructure layer boundaries.
Hardware degrades before it fails. The warning signs sit in counters nobody checks until the outage. Asama watches every host and compares each to its peers.
reallocated sectors · pending sectors · media & data integrity errors
lab-sf-118
CriticalToday · 13:08
SMART reports pre-failure on /dev/sdc (Seagate ST16000NM001G): Reallocated_Sector_Ct 248, above the vendor threshold of 36.
lab-sf-007
Warning15 days ago · 10:58
SMART media and data integrity errors on /dev/nvme1n1 rose to 19. No read failures yet.
Fleets drift quietly. An RMA’d chassis returns with vendor defaults. A change made during emergency is forgotten. Each machine looks fine alone, wrong beside its peers.
On lab-sf-156, the PxeDev3EnDis setting is Disabled, whereas the expected value is Enabled.
Impact
These BIOS/UEFI PXE network adapter settings can cause network boot availability and VLAN selection to differ from the peer cluster, potentially preventing access to the intended provisioning network.
Related anomalies
The hardest fault to catch isn’t a failure or a misconfiguration. The machine just stops performing to spec, with every number in range.
On lab-sf-019, CPU context switches are 70,233.39 switches/s, whereas the expected rate is 50,000–55,000 switches/s.
Impact
Excessive CPU context switching can consume processor time and reduce application performance, particularly under load.
Advisories tell you a version is affected. It is your job to find out which of your machines are running it, which are exposed, or which you can safely take down to patch.
Security update for Dell PowerEdge Server BIOS: improper privilege management
Advisory ID: DSA-2024-035
Vulnerability summary
A vulnerability in Dell PowerEdge Server BIOS allows a local attacker to escalate privileges on affected systems, compromising system integrity.
Incident times
From Sep 13 · 20:31 · To Now
Every PDU is mapped from inlet to outlet, with Critical and Warning faults that close themselves when the problem clears.
Each affected host is charted against its peers, so “abnormal” is obvious at a glance.
A new host agent adds network queue, PCIe error, GPU and VM metrics.
Yes, you can configure alerts and build dashboards. But we built Asama so that you do not have to do it in the first place. Asama ensures alerts arrive to you pre-filtered and with context. Thresholds are adjusted autonomously using our proprietary machine learning algorithms.
Yes. Asama integrates with Jira and other issue trackers, including Asana, ClickUp, monday.com and GitHub Issues.
Yes. Asama combines proprietary machine learning with statistical models to predict failures in components such as SSDs, HDDs and DIMMs.
No. Detection runs on read-only access, so Asama never changes your hosts. Credentials stay in a secret management vault inside your own infrastructure, and we never use your telemetry data to train our models.
Bring one recurring problem your current tooling hasn’t solved. We’ll show you how Asama detects it, finds the cause, and plans the fix.